      產(chǎn)品中心

      一步法人孕酮(PG)酶聯(lián)免疫吸附檢測試劑盒
      ELK045ES
      規(guī)格: 價格:
      64T ¥2660.00
      112T ¥3800.00

      Overview

      Product name: EasyStep Human PG(Progesterone) ELISA Kit
      Reactivity: Human
      Alternative Names: P4; Pregn-4-Ene-3,20-Dione
      Assay Type: Competitive Inhibition
      Sensitivity: 0.7 ng/mL
      Standard: 100 ng/mL
      Detection Range: 1.56-100 ng/mL
      Sample Type: Serum, plasma
      Assay Length: 1.5h
      Research Area: Endocrinology;Reproductive science;Hormone metabolism;
      Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human PG antigen, and the Human PG standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human PG to each microplate well and incubated . After TMB substrate solution is added, the enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ±10nm. The concentration of Human PG in the samples is then determined by comparing the OD of the samples to the standard curve.

      標準曲線

      Concentration (ng/mL) OD Corrected OD
      100.00 0.189
      50.00 0.386
      25.00 0.611
      12.50 0.823
      6.25 1.169
      3.13 1.592
      1.57 1.697
      0.00 2.213

      精密度

      Intra-assay Precision (Precision within an assay):CV%<8%

      Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

      Inter-assay Precision (Precision between assays):CV%<10%

      Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

      回收率

      Matrices listed below were spiked with certain level of recombinant PG and the recovery rates were calculated by comparing the measured value to the expected amount of PG in samples.
      Matrix Recovery range Average
      serum(n=5) 90-103% 96%
      EDTA plasma(n=5) 87-99% 93%
      Heparin plasma(n=5) 85-97% 91%

      線性

      The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PG and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
      Matrix 1:2 1:4 1:8 1:16
      serum(n=5) 87-102% 87-96% 92-101% 83-96%
      EDTA plasma(n=5) 85-97% 93-101% 97-103% 91-99%
      Heparin plasma(n=5) 86-93% 93-101% 85-98% 90-101%