      Overview

      Product name: EasyStep Mouse 25-OH-D(25 Hydroxy Vitamin D) ELISA Kit
      Reactivity: Mouse
      Alternative Names: 25 Hydroxy Vitamin D;
      Assay Type: Competitive Inhibition
      Sensitivity: 7.7 ng/mL
      Standard: 5000 ng/mL
      Detection Range: 78.13-5000 ng/mL
      Sample Type: Serum, plasma
      Assay Length: 1.5h
      Research Area: Reproductive science;Genetic science;Nutrition metabolism;Bone metabolism;
      Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Mouse 25-OH-D antigen, and the Mouse 25-OH-D standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Mouse 25-OH-D to each microplate well and incubated . After TMB substrate solution is added, the enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ±10nm. The concentration of Mouse 25-OH-D in the samples is then determined by comparing the OD of the samples to the standard curve.

      標(biāo)準(zhǔn)曲線

      Concentration (ng/mL) OD Corrected OD
      5000.00 0.175
      2500.00 0.352
      1250.00 0.577
      625.00 0.833
      312.50 1.152
      156.25 1.565
      78.13 1.789
      0.00 2.132

      精密度

      Intra-assay Precision (Precision within an assay):CV%<8%

      Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

      Inter-assay Precision (Precision between assays):CV%<10%

      Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

      回收率

      Matrices listed below were spiked with certain level of recombinant 25-OH-D and the recovery rates were calculated by comparing the measured value to the expected amount of 25-OH-D in samples.
      Matrix Recovery range Average
      serum(n=5) 95-107% 101%
      EDTA plasma(n=5) 82-95% 88%
      Heparin plasma(n=5) 78-96% 87%

      線性

      The linearity of the kit was assayed by testing samples spiked with appropriate concentration of 25-OH-D and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
      Matrix 1:2 1:4 1:8 1:16
      serum(n=5) 93-102% 81-96% 93-106% 82-95%
      EDTA plasma(n=5) 86-97% 83-96% 91-103% 96-105%
      Heparin plasma(n=5) 85-100% 80-97% 81-92% 87-103%