91尤物手机在线观看|欧美日韩国产在线观看网站|激情五月婷婷中文|伊人一区在线观看

<sup id="qlgan"><thead id="qlgan"><pre id="qlgan"></pre></thead></sup>
<ol id="qlgan"><nobr id="qlgan"><kbd id="qlgan"></kbd></nobr></ol>
  • <sup id="qlgan"></sup>
      <acronym id="qlgan"><dfn id="qlgan"><kbd id="qlgan"></kbd></dfn></acronym>

      產(chǎn)品中心

      一步法人基質(zhì)金屬蛋白酶8(MMP8)酶聯(lián)免疫吸附檢測試劑盒
      ELK070ES
      規(guī)格: 價(jià)格:
      64T ¥1960.00
      112T ¥2800.00

      Overview

      Product name: EasyStep Human MMP8(Matrix Metalloproteinase 8) ELISA Kit
      Reactivity: Human
      Alternative Names: CLG2; HNC; PMNL-CL; Collagenase 2; Neutrophil Collagenase; PMNL collagenase
      Assay Type: Sandwich
      Sensitivity: 24 pg/mL
      Standard: 10 ng/mL
      Detection Range: 0.16-10 ng/mL
      Sample Type: Serum, plasma
      Assay Length: 1.5h
      Research Area: Enzyme & Kinase;Infection immunity;Cardiovascular biology;
      Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MMP-8, and the Human MMP-8 standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human MMP-8. After TMB substrate solution is added, only those wells that contain Human MMP-8 and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MMP-8 in the samples is then determined by comparing the OD of the samples to the standard curve.

      標(biāo)準(zhǔn)曲線

      Concentration (ng/mL) OD Corrected OD
      10.00 2.231 2.127
      5.00 1.697 1.593
      2.50 1.069 0.965
      1.25 0.752 0.648
      0.63 0.451 0.347
      0.32 0.352 0.248
      0.16 0.228 0.124
      0.00 0.104 0.000

      精密度

      Intra-assay Precision (Precision within an assay):CV%<8%

      Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

      Inter-assay Precision (Precision between assays):CV%<10%

      Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

      回收率

      Matrices listed below were spiked with certain level of recombinant MMP-8 and the recovery rates were calculated by comparing the measured value to the expected amount of MMP-8 in samples.
      Matrix Recovery range Average
      serum(n=5) 87-99% 93%
      EDTA plasma(n=5) 85-97% 91%
      Heparin plasma(n=5) 90-103% 96%

      線性

      The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MMP-8 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
      Matrix 1:2 1:4 1:8 1:16
      serum(n=5) 85-92% 79-96% 92-101% 87-98%
      EDTA plasma(n=5) 92-105% 82-92% 86-94% 81-95%
      Heparin plasma(n=5) 86-93% 91-104% 87-98% 95-99%

      產(chǎn)品成分表

      關(guān)閉

      在線咨詢

      Online consultation

      • 在線咨詢
      • 技術(shù)支持

      關(guān)注微信公眾號

      微信掃一掃立即咨詢

      微信掃一掃立即咨詢

      關(guān)閉