      一步法人單核細(xì)胞趨化蛋白1(MCP1)酶聯(lián)免疫吸附檢測(cè)試劑盒
      ELK071ES
      規(guī)格: 價(jià)格:
      64T ¥2240.00
      112T ¥3200.00

      Overview

      Product name: EasyStep Human MCP1(Monocyte Chemotactic Protein 1) ELISA Kit
      Reactivity: Human
      Alternative Names: CCL2; GDCF2; HC11; HSMCR30; MCAF; MCP1; SCYA2; SMC-CF; Chemokine C-C-Motif Ligand 2; Monocyte Chemotactic And Activating Factor; Monocyte Secretory Protein JE
      Assay Type: Sandwich
      Sensitivity: 0.57 pg/mL
      Standard: 500 pg/mL
      Detection Range: 7.81-500 pg/mL
      Sample Type: Serum, plasma, cell culture supernatants
      Assay Length: 1.5h
      Research Area: Cytokine;Tumor immunity;Infection immunity;
      Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MCP1, and the Human MCP1 standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human MCP1. After TMB substrate solution is added, only those wells that contain Human MCP1 and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MCP1 in the samples is then determined by comparing the OD of the samples to the standard curve.

      標(biāo)準(zhǔn)曲線

      Concentration (pg/mL) OD Corrected OD
      500.00 2.168 2.067
      250.00 1.790 1.689
      125.00 1.114 1.013
      62.50 0.763 0.662
      31.25 0.542 0.441
      15.63 0.315 0.214
      7.82 0.138 0.037
      0.00 0.101 0.000

      精密度

      Intra-assay Precision (Precision within an assay):CV%<8%

      Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

      Inter-assay Precision (Precision between assays):CV%<10%

      Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

      回收率

      Matrices listed below were spiked with certain level of recombinant MCP1 and the recovery rates were calculated by comparing the measured value to the expected amount of MCP1 in samples.
      Matrix Recovery range Average
      serum(n=5) 89-101% 95%
      EDTA plasma(n=5) 82-95% 88%
      Heparin plasma(n=5) 80-94% 87%

      線性

      The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MCP1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
      Matrix 1:2 1:4 1:8 1:16
      serum(n=5) 85-95% 85-96% 93-99% 87-101%
      EDTA plasma(n=5) 86-95% 93-103% 87-98% 85-96%
      Heparin plasma(n=5) 93-102% 87-96% 85-98% 91-103%