      Overview

      Product name: Mouse EPO(Erythropoietin) ELISA Kit
      Reactivity: Mouse
      Alternative Names: EP; Epoetin; Erythropoetin; Hematopoietin; Hemopoietin
      Assay Type: Sandwich
      Sensitivity: 2.71 pg/mL
      Standard: 400 pg/mL
      Detection Range: 6.25-400 pg/mL
      Sample Type: serum, plasma, tissue homogenates, cell lysates and other biological fluids
      Assay Length: 3.5h
      Research Area: Cytokine;Endocrinology;Hematology;Hormone metabolism;
      Uniprot ID: P07321
      Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse EPO. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse EPO. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse EPO, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse EPO in the samples is then determined by comparing the OD of the samples to the standard curve.

      標準曲線

      Concentration (pg/mL) OD Corrected OD
      400.00 1.754 1.699
      200.00 1.203 1.148
      100.00 0.796 0.741
      50.00 0.441 0.386
      25.00 0.231 0.176
      12.50 0.145 0.090
      6.25 0.113 0.058
      0.00 0.055 0.000

      精密度

      Intra-assay Precision (Precision within an assay):CV%<8%

      Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

      Inter-assay Precision (Precision between assays):CV%<10%

      Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

      回收率

      Matrices listed below were spiked with certain level of recombinant EPO and the recovery rates were calculated by comparing the measured value to the expected amount of EPO in samples.
      Matrix Recovery range Average
      serum(n=5) 83-95% 89%
      EDTA plasma(n=5) 87-97% 90%
      Heparin plasma(n=5) 81-95% 88%

      線性

      The linearity of the kit was assayed by testing samples spiked with appropriate concentration of EPO and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
      Matrix 1:2 1:4 1:8 1:16
      serum(n=5) 85-93% 98-105% 87-98% 95-102%
      EDTA plasma(n=5) 88-95% 96-102% 89-103% 89-96%
      Heparin plasma(n=5) 87-101% 87-96% 82-93% 89-97%