91尤物手机在线观看|欧美日韩国产在线观看网站|激情五月婷婷中文|伊人一区在线观看

<sup id="qlgan"><thead id="qlgan"><pre id="qlgan"></pre></thead></sup>
<ol id="qlgan"><nobr id="qlgan"><kbd id="qlgan"></kbd></nobr></ol>
  • <sup id="qlgan"></sup>
      <acronym id="qlgan"><dfn id="qlgan"><kbd id="qlgan"></kbd></dfn></acronym>

      產(chǎn)品中心

      人FMS樣酪氨酸激酶3配體(Flt3L)酶聯(lián)免疫吸附檢測試劑盒
      ELK1021
      規(guī)格: 價(jià)格:
      48T ¥1680.00
      96T ¥2400.00

      Overview

      Product name: Human Flt3L(FMS Like Tyrosine Kinase 3 Ligand) ELISA Kit
      Reactivity: Human
      Alternative Names: FLT3LG; FLT3-LG; Flt3-L; FL; Fms-Related Tyrosine Kinase 3 ligand; SL cytokine
      Assay Type: Sandwich
      Sensitivity: 11.8 pg/mL
      Standard: 2000 pg/mL
      Detection Range: 31.25-2000 pg/mL
      Sample Type: serum, plasma, tissue homogenates and other biological fluids
      Assay Length: 3.5h
      Research Area: Cytokine;Immune molecule;Hematology;
      Uniprot ID: P49771
      Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human Flt3L. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human Flt3L. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human Flt3L, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human Flt3L in the samples is then determined by comparing the OD of the samples to the standard curve.

      標(biāo)準(zhǔn)曲線

      Concentration (pg/mL) OD Corrected OD
      2000.00 2.043 1.935
      1000.00 1.628 1.520
      500.00 1.263 1.155
      250.00 0.864 0.756
      125.00 0.539 0.431
      62.50 0.347 0.239
      31.25 0.216 0.108
      0.00 0.108 0.000

      精密度

      Intra-assay Precision (Precision within an assay):CV%<8%

      Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

      Inter-assay Precision (Precision between assays):CV%<10%

      Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

      回收率

      Matrices listed below were spiked with certain level of recombinant Flt3L and the recovery rates were calculated by comparing the measured value to the expected amount of Flt3L in samples.
      Matrix Recovery range Average
      serum(n=5) 78-90% 84%
      EDTA plasma(n=5) 84-97% 91%
      Heparin plasma(n=5) 89-105% 97%

      線性

      The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Flt3L and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
      Matrix 1:2 1:4 1:8 1:16
      serum(n=5) 95-103% 89-101% 87-98% 85-92%
      EDTA plasma(n=5) 88-102% 91-99% 83-95% 89-97%
      Heparin plasma(n=5) 85-94% 78-96% 79-93% 82-90%