91尤物手机在线观看|欧美日韩国产在线观看网站|激情五月婷婷中文|伊人一区在线观看

<sup id="qlgan"><thead id="qlgan"><pre id="qlgan"></pre></thead></sup>
<ol id="qlgan"><nobr id="qlgan"><kbd id="qlgan"></kbd></nobr></ol>
  • <sup id="qlgan"></sup>
      <acronym id="qlgan"><dfn id="qlgan"><kbd id="qlgan"></kbd></dfn></acronym>

      產(chǎn)品中心

      人生長調(diào)節(jié)致癌基因a(GROa/CXCL1)酶聯(lián)免疫吸附檢測(cè)試劑盒
      ELK1024
      規(guī)格: 價(jià)格:
      48T ¥1680.00
      96T ¥2400.00

      Overview 文獻(xiàn)

      Product name: Human GROa/CXCL1(Growth Regulated Oncogene Alpha) ELISA Kit
      Reactivity: Human
      Alternative Names: CXCL1; GRO1; GROa; GRO-A; MGSA-A; NAP3; SCYB1; Chemokine C-X-C-Motif Ligand 1; Melanoma Growth Stimulating Activity Alpha; Fibroblast Secretory Protein; Neutrophil Activating Protein 3
      Assay Type: Sandwich
      Sensitivity: 5.8 pg/mL
      Standard: 1000 pg/mL
      Detection Range: 15.63-1000 pg/mL
      Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
      Assay Length: 3.5h
      Research Area: Cytokine;Tumor immunity;Infection immunity;
      Uniprot ID: P09341
      Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human GROa/CXCL1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human GROa/CXCL1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human GROa/CXCL1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GROa/CXCL1 in the samples is then determined by comparing the OD of the samples to the standard curve.

      標(biāo)準(zhǔn)曲線

      Concentration (pg/mL) OD Corrected OD
      1000.00 2.168 2.027
      500.00 1.841 1.700
      250.00 1.384 1.243
      125.00 0.969 0.828
      62.50 0.649 0.508
      31.25 0.481 0.340
      15.63 0.315 0.174
      0.00 0.141 0.000

      精密度

      Intra-assay Precision (Precision within an assay):CV%<8%

      Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

      Inter-assay Precision (Precision between assays):CV%<10%

      Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

      回收率

      Matrices listed below were spiked with certain level of recombinant GROa/CXCL1 and the recovery rates were calculated by comparing the measured value to the expected amount of GROa/CXCL1 in samples.
      Matrix Recovery range Average
      serum(n=5) 82-97% 89%
      EDTA plasma(n=5) 95-107% 101%
      Heparin plasma(n=5) 81-95% 88%

      線性

      The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GROa/CXCL1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
      Matrix 1:2 1:4 1:8 1:16
      serum(n=5) 85-101% 78-96% 79-98% 93-102%
      EDTA plasma(n=5) 88-97% 91-103% 86-92% 89-97%
      Heparin plasma(n=5) 88-104% 87-96% 85-93% 82-90%
      關(guān)閉

      在線咨詢

      Online consultation

      • 在線咨詢
      • 技術(shù)支持

      關(guān)注微信公眾號(hào)

      微信掃一掃立即咨詢

      微信掃一掃立即咨詢