      小鼠粒細(xì)胞集落刺激因子(GCSF)酶聯(lián)免疫吸附檢測(cè)試劑盒
      ELK1026
      規(guī)格: 價(jià)格:
      48T ¥1680.00
      96T ¥2400.00

      Overview

      Product name: Mouse GCSF(Colony Stimulating Factor 3, Granulocyte) ELISA Kit
      Reactivity: Mouse
      Alternative Names: CSF3; G-CSF; Granulocyte Colony Stimulating Factor; Pluripoietin; Filgrastim; Lenograstim
      Assay Type: Sandwich
      Sensitivity: 2.8 pg/mL
      Standard: 500 pg/mL
      Detection Range: 7.82-500 pg/mL
      Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
      Assay Length: 3.5h
      Research Area: Cytokine;Hematology;
      Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse GCSF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse GCSF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse GCSF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse GCSF in the samples is then determined by comparing the OD of the samples to the standard curve.

      標(biāo)準(zhǔn)曲線

      Concentration (pg/mL) OD Corrected OD
      500.00 1.961 1.874
      250.00 1.487 1.400
      125.00 0.924 0.837
      62.50 0.629 0.542
      31.25 0.428 0.341
      15.63 0.218 0.131
      7.82 0.190 0.103
      0.00 0.087 0.000

      精密度

      Intra-assay Precision (Precision within an assay):CV%<8%

      Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

      Inter-assay Precision (Precision between assays):CV%<10%

      Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

      回收率

      Matrices listed below were spiked with certain level of recombinant GCSF and the recovery rates were calculated by comparing the measured value to the expected amount of GCSF in samples.
      Matrix Recovery range Average
      serum(n=5) 81-95% 88%
      EDTA plasma(n=5) 86-99% 92%
      Heparin plasma(n=5) 89-105% 97%

      線性

      The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GCSF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
      Matrix 1:2 1:4 1:8 1:16
      serum(n=5) 85-92% 95-103% 97-105% 93-102%
      EDTA plasma(n=5) 98-105% 86-92% 91-103% 89-97%
      Heparin plasma(n=5) 95-106% 87-96% 82-90% 92-101%